Error Code
617
Problem Solving
15
027-446
[Cause] The IP address of IPv6 set manually already exists.
[Remedy] Change the [Manually Configured IPv6 Address] on the
machine, or the IP address of IPv6 on the network device, to
remove the duplication of addresses.
027-447
[Cause] The IP address of IPv6 network already exists.
[Remedy] Change the [Link-local Address] for IPv6 on the machine, or the
IP address of IPv6 on the network device, to remove the
duplication of addresses.
027-452
[Cause] IP address of IPv4 already exists.
[Remedy] Change the IP address of IPv4 set on the machine or the IP
address of IPv4 on the network device.
027-500
[Cause] Unable to connect to the SMTP server.
[Remedy] Specify the SMTP server name correctly or specify the server by
using its IP address.
027-501
[Cause] A POP server error occurred.
[Remedy] Execute the operation again. If the error still is not resolved,
contact our Customer Support Center.
027-502
[Cause] Failed to log into the POP3 server when using the POP3 protocol.
[Remedy] Confirm whether the user name and password used in the POP3
server are correct on CentreWare Internet Services.
027-503
[Cause] A POP server error occurred.
[Remedy] Execute the operation again. If the error still is not resolved,
contact our Customer Support Center.
027-504
[Cause] An SMTP server error occurred.
[Remedy] Execute the operation again. If the error still is not resolved,
contact our Customer Support Center.
027-513
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because access to the SMB server was not permitted.
When the server is Macintosh, a folder with the same name as
the specified file name may exist on the server.
[Remedy] Consult your system administrator for settings.
027-514
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because an error has been occurred between the SMB
server and the DNS server.
[Remedy] Check the following conditions:
z
The SMB server is connected to the DNS server.
z
The SMB server name is registered on the DNS server.
027-515
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because an error has been occurred.
[Remedy] Take the following measures:
z
Set the DNS server address.
z
Set the target SMB server address using IP address.
Error Code
Cause and Remedy

Table of Contents

Other manuals for Fuji Xerox ApeosPort-VI C3370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox ApeosPort-VI C3370 and is the answer not in the manual?

Fuji Xerox ApeosPort-VI C3370 Specifications

General IconGeneral
Print Resolution1200 x 2400 dpi
Copy Resolution600 x 600 dpi
Scan Resolution600 x 600 dpi
FunctionsPrint, Copy, Scan, Fax (optional)
Fax Speed33.6 kbps
Print Speed33 ppm (black/color)
ConnectivityEthernet, USB, Wi-Fi
Memory4 GB
Paper Input Capacity1, 140 sheets
Paper Output Capacity250 sheets
Supported Paper SizesA3, A4, A5, B4, B5, Legal, Letter, Executive, Folio, Oficio
Duplex PrintingYes
PDLPCL6, PostScript 3
Copy Speed33 ppm (color/black)

Related product manuals