Multipath Configuration
A multipath configuration connects the
ETERNUS DX to a server via multiple paths (multipath). Sys-
tem reliability is improved due to the path redundancy.
If a path fails, access can continue by using the path failover function that switches access from the
failed path to another path.
Figure 85 Multipath Connection (When a SAN Connection Is Used — Basic Connection Configuration)
Server
HBA HBA
Server
HBAHBA
ETERNUS DX
CM#0
Port
Port
CA#0 CA#0
CM#1
Port
Port
Figure 86 Multipath Connection (When a SAN Connection Is Used — Switch Connection)
Server
HBA
HBA
Server
HBA
HBA
Server
HBA
HBA
Switch Switch
ETERNUS DX
CM#0
CA
Port
Port
CA
CM#1
Port Port
4. Connection Configuration
SAN Connection
150
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
Design Guide (Basic)
Copyright 2023 Fujitsu Limited
P3AM-7642-32ENZ0