The following figure provides connection examples and explains the necessary preparation for
when the IP address of the Slave CM is set.
For the ETERNUS DX
, three IP addresses are required (two IP addresses for the MNT ports and
one IP address for the RMT port).
Figure 98 Connection Example When the IP Address of the Slave CM Is Set (and a Dedicated Remote
Support Port Is Used)
Different LANs are used for MNT ports and RMT ports.
The IP addresses of the Master CM and the Slave CM are set.
LAN for operation management
LAN switch
ETERNUS DX
Controller enclosure
RMT
MNT
CM#0
RMT
CM#1
Router
Remote support
c
enter
SNMP
manager
NTP server
E-mail server
Authentication
server
Syslog server
Administration
terminal
IP address A IP address BIP address C
MNT
LAN Control (Master CM/Slave CM)
This section explains how the LAN control controller of the ETERNUS DX operates.
When an ETERNUS DX has two controllers, the controller (CM) that is given the authority to man-
age the LAN is called the Master CM and the other CM is called the Slave CM.
When an error occurs in the Master CM or LAN, the Master CM is switched automatically.
4. Connection Configuration
LAN Connection
161
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
Design Guide (Basic)
Copyright 2023 Fujitsu Limited
P3AM-7642-32ENZ0