For a Cascade Copy, the copy destination area for copy session 1 and the copy source area for
copy session 2 must be identical or the entire copy source area for copy session 2 must be included
in the copy destination area for copy session 1.
A Cascade Copy can be performed when all of the target volumes are the same size or when the
copy destination volume for copy session 2 is larger than the other volumes.
Figure 57 Cascade Copy
Copy source Copy destination
and s
ource
Copy destination
O
PC/QuickOPC/
EC/REC
OPC/QuickOPC/
SnapOPC/
SnapOPC+/EC/REC
: Copy session 1
: Copy session 2
1 2
Copy source Copy destination
and source
Copy destination
OPC/QuickOPC/
EC/REC
OPC/QuickOPC/
SnapOPC/
SnapOPC+/EC/REC
1 2
Table 33
shows the supported combinations when adding a copy session to a copy destination vol-
ume where a copy session has already been configured.
Table 33 Available Cascade Copy Combinations (When a Cascade Copy Performs Session 1 Followed
by Session 2)
Copy session 2
Copy session 1
OPC QuickOPC SnapOPC SnapOPC+ EC
REC synchro-
nous trans-
mission
REC Stack
mode
REC Consistency
mode
OPC ¡ (*1) ¡ (*1)
´ ´
¡ ¡ ¡ ¡
QuickOPC ¡ (*1) ¡ (*1) (*2)
´ ´
¡ ¡ ¡ ¡
SnapOPC ¡ (*1) ¡ (*1)
´ ´
¡ ¡ ¡ ¡
SnapOPC+ ¡ (*1) ¡ (*1)
´ ´
¡ ¡ ¡ ¡
EC
¡ ¡
´ ´
¡ ¡ ¡ ¡
REC synchro-
nous transmis-
sion
¡ (*3) ¡ (*3)
´ ´
¡ (*3) ¡ (*3) ¡ (*3)
¡
(*3) (*4)
REC Stack
mode
¡ ¡
´ ´
¡ ¡ ¡ ¡
REC Consisten-
cy mode
¡ (*3) ¡ (*3)
´ ´
¡ (*3)
¡
¡ (*3)
¡
(*3) (*4)
¡: Possible, ´: Not possible
*1 : When copy session 2 is an OPC, QuickOPC, SnapOPC, or SnapOPC+ session, data in the copy
destination of copy session 1 is backed up. Data is not backed up in the copy source of copy
session 1.
*2: The supported modified data size varies depending on the controller firmware version.
2. Basic Functions
Backup (Advanced Copy)
98
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
Design Guide (Basic)
Copyright 2023 Fujitsu Limited
P3AM-7642-32ENZ0