Fujitsu ETERNUS DX100 S3 - Host Interface; Figure 111 Installation Diagram for Host Interfaces (When Only One Controller Is Installed); Figure 112 Host Interface Installation Diagram 1 (When Two Controllers Are Installed in the ETERNUS DX100 S4;DX100 S3); Figure 113 Host Interface Installation Diagram 2 (When Two Controllers Are Installed in the ETERNUS DX100 S4;DX100 S3)

Fujitsu ETERNUS DX100 S3
207 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Host Interface
This section describes the standard installation rules for host interfaces.
When Only One Controller Is Installed
Install CA#0 first, and then install CA#1.
Figure 111 Installation Diagram for Host Interfaces (When Only One Controller Is Installed)
Port
#0
Por
t
#1
CA#1
Port
#0
Por
t
#1
CA#0
Controller 0 (CM#0)
Expansion
Rear view of a controller enclosure
When Two Controllers Are Installed
Installation Order for the
ETERNUS DX100 S4/DX100 S3
Install the host interfaces in CA#0 first, and then install CA#1.
The configuration is the same for Controller 0 (CM#0) and Controller 1 (CM#1).
Note that the positions of CA#0 and CA#1 depend on the controller type.
If an FC 16Gbit/s or FC 8Gbit/s is installed in the controller as the standard host interface, CA#0 is
located on the right side of the controller.
Figure 112 Host Interface Installation Diagram 1 (When Two Controllers Are Installed in the ETERNUS
DX100 S4/DX100 S3)
Controller 0 (CM#0) Controller 1 (CM#1)
Port
#0
Port
#1
CA#1
Port
#0
Por
t
#1
CA#0
Port
#0
Port
#1
CA#1
Port
#0
Por
t
#1
CA#0
Expansion Expansion
R
ear view of a controller enclosure
If an FC 16Gbit/s or FC 8Gbit/s that is sold separately from the controller is installed as the standard
host interface or if an FC 32Gbit/s, an iSCSI, an SAS, an FCoE, or an Ethernet is installed in the con-
troller as the standard host interface, CA#0 is located on the left side of the controller.
Figure 113 Host Interface Installation Diagram 2 (When Two Controllers Are Installed in the ETERNUS
DX100 S4/DX100 S3)
Controller 0 (CM#0) Controller 1 (CM#1)
Port
#0
Por
t
#1
CA#1
Port
#0
Por
t
#1
CA#0
Port
#0
Por
t
#1
CA#1
Port
#0
Por
t
#1
CA#0
Expansion Expansion
R
ear view of the controller enclosure
5. Hardware Configurations
Standard Installation Rules
186
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems
Design Guide (Basic)
Copyright 2023 Fujitsu Limited
P3AM-7642-32ENZ0

Table of Contents

Other manuals for Fujitsu ETERNUS DX100 S3

Related product manuals