The procedure to modify REC multiplicity is as follows:
Procedure
1 Click the [Modify REC Multiplicity] in [Action].
2 Specify the multiplicity.
The main setting items are as follows.
Remote Box ID List
Priority Level
Specification Mode
Multiplicity
3 Click the [Set] button
A confirmation screen appears.
4 Click the [OK] button.
The REC multiplicity settings starts.
5 Click the [Done] button to return to the [Copy Path] screen.
End of procedure
When "Manual" is selected for "Specification Mode" and numeric characters exceed the allowed range
(from 1 to 1024), an error screen appears. If this occurs, check the parameter settings.