Panic
Collection Mode
A.1.4 Utility Management
A.1.4.1 Backup Configuration
For details about this function, refer to "1.5.2 Backup Configuration" (page 66).
For the factory default settings for this function, refer to "Appendix B Backup Configuration" (page 975)
.
Select Configuration Definition
Configuration Definition Data
Note (text box)
Description Select the collection mode for panic dump.
Input condition/
Display contents
Nose and Tail Mode
The latest and oldest panic dumps are saved.
Fortnight Mode
The first and second panic dumps are saved.
Off
Does not save panic dumps.
Description Select configuration definition data that is to be backed up.
If "Configuration (1 time before)", or "Configuration (2 times before)" do not exist, the
corresponding configuration definition data cannot be selected.
Input condition/
Display contents
Configuration (Latest)
Configuration (1 time before)
Configuration (2 times before)
Description In the "Note" field, remarks which have been added to the selected configuration
definition data to be backed up are displayed.
If no remarks exist, this field is blank. The "Note" field can be edited (input).
Input condition/
Display contents
Up to 16 alphanumeric characters and symbols (except "," (comma) and "?")