EasyManua.ls Logo

Fujitsu Eternus DX600 S3 - A.4 Connectivity Management

Fujitsu Eternus DX600 S3
1082 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A Parameter List
A.4 Connectivity Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
816
A.4 Connectivity Management
This section provides information on the parameters of the following actions for connectivity management.
Host Affinity Management
Host Group Management
CA Port Group Management
LUN Group Management
Host Response Management
Host-LU QoS Management
NAS Management
A.4.1 Host Affinity Management
A.4.1.1 Create Host Affinity
For details about this function, refer to "4.1.1 Create Host Affinity" (page 338).
For the factory default settings for this function, refer to "Appendix B Create Host Affinity" (page 993)
.
Target Connection Setting
Target Connection
Select CA Port
Checkbox to select a CA port
Description Select the connection target from "Host Group - CA Port Group" or "Host - CA Port".
Input condition/
Display contents
Host Group - CA Port Group
Specify a "Host Group", a "CA Port Group", and a "LUN Group" to create a host affinity.
Host - CA Port
Specify a "Host", a "CA Port", and a "LUN Group" to create a host affinity.
Description To enable the paths between hosts and ports, select the port checkboxes. To disable the
paths, clear the checkboxes.
Select this item only when the connection target is "Host Group - CA Port Group".
Input condition/
Display contents
Checkbox
Selected
Cleared

Table of Contents

Other manuals for Fujitsu Eternus DX600 S3