Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
740
Out of NAS File Management Domain
Succeed NAS Snapshot
Fall below NAS Quota Limit
Automatic Change Storage Cluster Active/Standby State
Manual Change Storage Cluster Active/Standby State
Connect Storage Cluster Controller
Description Select whether to notify when insufficient capacity in the management area for the files
and the directories of the NAS function is detected in the NAS system. When notifying,
select the notification method.
This item is only displayed in a Unified Storage environment.
Description Select whether to notify when a Snapshot acquisition has succeeded in the NAS system.
When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description Select whether to notify when the Quota configuration information (Drive Used Size or
File Count) for users or groups becomes less than the threshold in the NAS system. When
notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
The relevant event is notified when both the warning and limit values are specified and the status changes as
described below.
- Exceeds the warning value Less than the warning value
- Exceeds the limit value Less than the warning value
The relevant event is notified when only the limit value is specified and the status changes as described below.
- Exceeds the limit value Less than the limit value
The relevant event is notified when only the warning value is specified and the status changes as described
below.
- Exceeds the warning value Less than the warning value
Description Select whether to notify when the Storage Cluster status is changed from "Standby" to
"Active" or from "Active" to "Standby" with automatic failover or failback. When notifying,
select the notification method. This item is only displayed when "Enable" is selected for
the Storage Cluster function.
Description Select whether to notify when the Storage Cluster status is changed from "Standby" to
"Active" or from "Active" to "Standby" with manual failover or failback. When notifying,
select the notification method. This item is only displayed when "Enable" is selected for
the Storage Cluster function.
Description Select whether to notify when communication with the paired storage system is
recovered if the Storage Cluster controller has been specified. When notifying, select the
notification method.
This item is only displayed when "Enable" is selected for the Storage Cluster function.