Servicing the Tape Library
5.1 Possible Tools Needed
■ To service a library you may need one or more of the following tools:
• Flat-blade screwdrivers (large and small)
• #3 Phillips screwdriver
• Cross-slot screwdriver
• Ground strap
5.2 Electrostatic Discharge
■ To prevent electrostatic damage, observe the following precautions:
• Transport products in static-safe containers such as conductive tubes, bags, or boxes.
• Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
• Cover the library with approved static-dissipating material. Provide a wrist strap connected to the work
surface and properly grounded tools and equipment.
• Keep the work area free of no conducting materials, such as ordinary plastic assembly aids and foam
packing.
• Make sure you are always properly grounded when touching a static-sensitive component or assembly.
• Avoid touching pins, leads, or circuitry.
• Use conductive field service tools.
CAUTION
A discharge of static electricity can damage static-sensitive devices or micro
circuitry. Proper packaging and grounding techniques are necessary precautions
to prevent damage.