Remarks
-
The
product
model
number
of
a
chassis
in
which
SPARC64
X+
processors
are
mounted
begins
with
"SPMCG".
Check
the
model
indication
on
the
label
affixed
on
the
upper
right
of
the
front
cover
or
check
the
system
nameplate
on
the
right
side
surface
of
the
chassis.
Table
8-2
  
Relationship
between
the
CPU
configuration
and
firmware
update
CPU
configuration
of
the
physical
partition
before
addition
CPU
configuration
of
the
chassis
to
be
added
XCP
firmware/Oracle
Solaris
SPARC64
XSPARC64
X+ Update
to
versions
supporting
SPARC64
X+
is
required
beforehand.
(*1)
SPARC64
X+
SPARC64
X+ Update
is
not
required
beforehand.
(*2)
SPARC64
X+
and
X
mixed
SPARC64
X+ Update
is
not
required
beforehand.
(*2)
SPARC64
X+
SPARC64
X Update
is
not
required
beforehand.
(*2)
chassis)
to
the
8BB
configuration
changes
the
master
chassis
from
the
SPARC
M10-4S
to
a
crossbar
box
mounted
in
an
expansion
rack.
The
existing
SPARC
M10-4S
must
be
released
from
the
system
before
installation
of
the
expansion
rack.
Multiple
SPARC
M10-4S
units
cannot
be
released
at
the
same
time.
Do
this
work
on
one
unit
at
a
time.
Any
installation
that
changes
the
8BB
configuration
to
the
9BB
configuration
or
larger
requires
the
new
installation
of
expansion
rack
2.
For
details
of
expansion
racks,
see
"2.4
Confirming
Rack
Specifications."
Any
installation
that
changes
the
8BB
configuration
to
the
9BB
configuration
or
larger
requires
special
attention
because
crossbar
cables
need
to
be
laid
all
over
again.
Executing
the
addfru
command
for
installation
automatically
updates
firmware
to
match
firmware
versions.
The
update
matches
the
version
on
the
master
XSCF,
so
we
recommend
updating
XCP
on
the
master
XSCF
to
the
latest
version
in
advance.
Suppose
you
install
the
SPARC
M10-4S
together
with
a
PCI
expansion
unit
connected
to
it
and
set
the
enabling/disabling
setting
of
the
direct
I/O
function
of
the
PCI
expansion
unit.
In
this
case,
execute
the
setpciboxdio
command
to
set
the
enabling/disabling
setting
before
installing
it
on
the
physical
partition
by
executing
the
addboard
command.
Set
the
setting.
When
you
have
changed
the
setting
of
the
direct
I/O
function,
do
not
restart
the
logical
domains
until
you
execute
the
ldm
add-spconfig
command
to
save
the
logical
domain
configuration
in
XSCF.
When
installing
a
SPARC
M10-4S
on
which
SPARC64
X+
processors
are
mounted
in
a
system
in
which
only
SPARC64
X
processors
are
mounted,
update
the
XCP
firmware
and
Oracle
Solaris
beforehand.
For
details,
see
"A.5
For
Expansion
of
the
System
Board
Configured
by
SPARC64
X+
Processor
to
the
Physical
Partition
Configured
Only
by
the
SPARC64
X
Processor"
in
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
July
2015230

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals