EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #273 background imageLoading...
Page #273 background image
co
n
n
ected
to
it
and
set
the
e
n
abli
n
g
/
disabli
n
g
setti
n
g
of
t
h
e
direct
I
/
O
function
of
the
PCI
expansion
unit.
In
this
case,
execute
the
setpciboxdio
command
to
set
the
enabling/disabling
setting
before
installing
it
on
the
physical
partition
by
executing
the
addboard
command.
When
you
have
changed
the
setting
of
the
direct
I/O
function,
do
not
restart
the
logical
domains
until
you
execute
the
ldm
add-spconfig
command
to
save
the
logical
domain
configuration
in
XSCF.
Note
-
Pull
out
all
the
PCIe
cassettes
with
the
PCIe
card
for
the
PCI
expansion
unit
to
be
installed.
After
incorporating
the
link
card
into
the
server,
attach
the
pulled-out
PCIe
cassette
to
the
PCI
expansion
unit.
Then,
install
the
PCIe
card
of
the
PCI
expansion
unit
on
the
server
by
using
PHP.
XSCF>

showboards

-p

0
PSB

PPAR-ID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault
----

------------

-----------

----

----

----

-------

--------
00-0

00(00)

Assigned

n

n

n

Passed

Normal

01-0

00(01)

Assigned

n

n

n

Passed

Normal
02-0

SP

Available

n

n

n

Passed

Normal
XSCF>

addboard

-c

assign

-p

0

02-0
PSB#02-0

will

be

assigned

into

PPAR-ID

0.

Continue?[y|n]

:
y
XSCF>

showresult
0
XSCF>

showboards

-p

0
PSB

PPAR-ID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault
----

------------

-----------

----

----

----

-------

--------
00-0

00(00)

Assigned

n

n

n

Passed

Normal

01-0

00(01)

Assigned

n

n

n

Passed

Normal
02-0

00(02)

Assigned

n

n

n

Passed

Normal
a.
Return
to
the
XSCF
shell,
execute
the
show boards
command,
and
check
the
system
board
(PSB)
status.
In
the
following
example,
system
board
02-0
is
in
the
system
board
pool.
b.
Execute
the
addboard
command
to
assign
the
system
board
(PSB).
The
following
example
assigns
system
board
02-0
to
physical
partition
0.
c.
Execute
the
showre sult
command
to
confirm
the
end
statu s
of
the
previously
executed
addboard
command.
In
the
following
example,
0
is
returned
as
the
end
status,
so
the
execution
of
the
addboard
command
has
completed
correctly.
d.
Execute
the
showbo ards
command
to
check
the
system
board
(PSB)
statu s ,
and
confirm
that
the
system
board
(PSB)
has
been
added.
13.
Start
the
physical
partition.
The
following
example
starts
PPAR#0.
Chapter
9
 
Installing
a
System
with
a
Building
Block
Configuration 259

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals