EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #280 background imageLoading...
Page #280 background image
Note
-
The
device
serial
of
either
the
master
XSCF
or
standb y
XSCF
is
used
as
the
representative
device
serial.
If
the
device
serial
of
the
standby
XSCF
is
being
used
as
the
representative
device
serial,
the
initbb
command
cannot
release
the
standby
chassis.
In
this
case,
execute
the
switchscf
command
to
switch
the
master
XSCF.
XSCF>
poweroff
-y
-a
PPAR-IDs
to
power
off:00,01,02
03
Continue?
[y|n]:y
00:Powering
off
01:Powering
off
02:Powering
off
03:Powering
off
connections.
To
move
the
SPARC
M10-4S
to
an
expansion
rack,
stop
the
entire
system
and
then
perform
the
work.
Note
the
following
points
on
this
work.
All
the
system
setting
information
will
be
cleared
and
reset
to
the
factory
defaults.
Before
removing
the
SPARC
M10-4S,
save
the
system
setting
information
with
the
dumpconfig
command.
In
case
of
resetting
the
configuration
to
the
original
setting,
you
can
restore
the
saved
setting
information
to
XSCF
by
using
the
restoreconfig
command.
Multiple
SPARC
M10-4S
units
cannot
be
released
from
the
system
by
using
the
initbb
command
at
the
same
time.
The
serial
number
of
the
chassis
of
either
the
master
XSCF
or
standby
XSCF
is
used
as
the
system
serial
number.
If
the
serial
number
of
the
standby
chassis
is
being
used
as
the
system
serial
number,
the
initbb
command
cannot
release
the
standby
chassis.
In
this
case,
execute
the
switchscf
command
to
switch
the
master
XSCF.
For
the
initialization
of
the
chassis
of
the
master
XSCF,
perform
that
work
at
the
end.
Execute
the
restoredefaults
-c
factory
command
to
return
to
the
factory
defaults,
including
the
CPU
Activation
key
information.
Perform
this
work
with
a
serial
connection
to
the
master
XSCF.
For
XCP
2041
or
later,
execute
the
restoredefaults
-c
factory
-r
activation
command.
The
key
must
be
reinstalled
at
initial
setup
of
the
XSCF
after
installation.
1.
Log
in
to
the
mast er
XSCF.
2.
Execute
the
showhardconf
command,
and
confirm
the
chassis
serial
number
of
the
system
board
(PSB)
targeted
for
release.
For
details,
see
"A.2.1
Checking
the
component
status."
3.
Execute
the
poweroff
command
to
stop
all
the
physical
partitions.
4.
Execute
the
deleteboard
command
from
the
mast er
XSCF
to
release
a
system
board
(PSB)
from
the
physical
partition
configuration.
The
following
example
releases
system
boards
00-0,
01-0,
02-0,
and
03-0
from
the
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
July
2015266

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals