XSCF>
poweroff
-y
-p
0
PPAR-IDs
to
power
off:00
Continue?
[y|n]:
y
00:Powering
off
*Note*
This
command
only
issues
the
instruction
to
power-off.
The
result
of
the
instruction
can
be
checked
by
the
"showpparprogress".
XSCF>
showpcl
-p
0
PPAR-ID
LSB
PSB
Status
00

Powered
Off

00

00-0

01

01-0
XSCF>
deleteboard
-c
unassign
01-0
PSB#01-0
will
be
unassigned
from
PPAR
immediately.
Continue?[y|n]
:
y
XSCF>
showresult
0
XSCF>
showboards
-a
PSB

PPAR-ID(LSB)
Assignment

Pwr

Conn
Conf
Test

Fault
----
------------
-----------
----
----
----
-------
--------
00-0
00(00)

Assigned

n

n

n

Passed

Normal
01-0
SP

Available

n

n

n

Passed

Normal
4.
Execute
the
show pcl
command,
and
confirm
that
the
power
of
the
physical
partition
has
been
turned
off.
5.
Execute
the
deleteboard
command
from
the
master
XSCF
to
release
a
system
board
(PSB)
from
the
physical
partition
configuration.
The
following
example
releases
system
board
01-0
from
the
physical
partition.
6.
Execute
the
showre sult
command,
and
confirm
the
end
statu s
of
the
previously
executed
deleteboard
command.
In
the
following
example,
0
is
returned
as
the
end
status,
so
the
execution
of
the
deleteboard
command
has
completed
correctly.
7.
Execute
the
show boards
command,
and
confirm
that
the
released
system
board
(PSB)
is
in
pool
state.
In
the
following
example,
system
board
01-0
is
in
the
system
board
pool.
8.
Execute
the
initbb
command
from
the
master
XSCF
to
release
the
target
SPARC
M10-4S
from
the
system
and
initialize
it.
In
bb_id,
specify
the
ID
(BB-ID)
identifying
the
chassis.
Chapter
10
 
Removing
a
System
with
a
Building
Block
Configuration 289

Table of Contents