14 Operating manual RX300 S3
Features Introduction
appropriately in the BIOS; see BIOS Setup under Related Publications on
page 103). The deactivated memory bank is no longer used and the faulty
memory module can be replaced at the next opportunity. In order to be able to
use the hot-spare memory function, all occupied memory banks must have an
identical memory configuration.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the case of an error and automatically hides the defective system components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens
Computers analyzes and monitors all components important for system
reliability.
Optional RAID functionality of the onboard SAS controller supports RAID Levels
0, 1, 10, 5 and 50 and increase system availability.
The hot-plug HDD modules provide additional availability.
Server management
Server management is implemented with the aid of the supplied ServerView
software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu
Siemens Computers. PDA reports the threat of a system error or overloading
early on so that preventative measures can be taken.
ServerView enables the management of all PRIMERGY servers in the network
via a central console. The following key features are supported among others
by ServerView in this context.
Remote power-on (Wake On LAN)
Temperature monitoring of the CPU and the surrounding area
Monitoring of the utilization of the PCI buses
Detailed status and error reports for bus systems, processors and main
memory
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event of failure of memory modules or processors
Power monitoring
Early detection of a defective fan
Watchdog timer for operating system monitoring and application monitoring
with ASR&R