18 Operating manual RX300 S3
Notational Conventions Introduction
1.3 Notational Conventions
The following notational conventions are used in this manual:
1.4 Technical Data
Electrical data (hot-swap power supply unit)
National and international standards
text in italics indicate commands, menu items or software programs
„Quotation marks“ indicate names of chapters and terms that are being
emphasized
Ê describes activities that must be performed in the order
shown
V CAUTION! pay particular attention to texts marked with this
symbol; failure to observe this warning may endanger
your life, destroy the system or lead to the loss of data
I indicates additional information, notes and tips
Power supply unit Multi-range
Rated voltage range 100 V - 240 V
Frequency 50 Hz - 60 Hz
Rated current in basic configuration: 4,2 A - 1,4 A / 100 V - 240 V
Max. rated current 8,5 A - 3,8 A / 100 V -240 V
Effective power 681 W
Apparent power 689 VA
Heat dissipation 2452 kJ/h (2324 btu/h)
Main power fuse 16 A
Protection class I
Product safety IEC 60950-1 / EN 60950-1 / UL 60950-1,
CAN/CSA-C22.2 No. 60950-1