RX300 S3 Operating manual 45
Hardware Installation Connecting the Server to the Line Voltage
You find two additional USB ports (1) on the front of the server (figure 11).
Figure 11: Front side: USB ports 3 and 4
Connecting the keyboard, mouse and monitor
Ê Connect the monitor, the keyboard and mouse to the standard ports of the
server (see table and figure 10 on page 44).
I If a separate graphics card is installed in a slot, the graphic controller on
the system board is automatically deactivated. The corresponding
monitor port can not be used. Plug the data cable of the monitor into the
monitor port of the graphics card.
Ê Connect the power cable of the monitor to the mains socket strip of the rack.
V CAUTION!
The rated current for the monitor can be found on the technical data label
on the monitor or in the operating manual for the monitor.
4.4 Connecting the Server to the Line Voltage
In its basic configuration level the server has a hot-plug power supply unit. A
second hot-plug e power supply unit can be added to achieve redundant power
supply. If a defect occurs in one power supply unit, the respective other power
supply unit ensures further operation.
!