EasyManuals Logo

Fujitsu Primergy RX300 S3 Operating Manual

Fujitsu Primergy RX300 S3
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
90 Operating manual RX300 S3
Hot-plug PCI Boards Hot-plug Components
Ê Place the removed fan away from the server.
V CAUTION!
Never place the removed/defective fan within the server, thus
preventing a short circuit.
Ê Pull the green handle of the new fan, insert the fan into the fan cartridge and
push the handle into position to engage the locking mechanism.
I The fans in the new fan unit are measured via express commands in
the server management. As a function of the results the LED (see
figure 28 on page 89) is set to light up green (fan o.k.) or to light up
orange (fan defective).
Ê Replace the housing cover (see section Opening/Closing the Housing on
page 95).
8.4 Replacing hot-plug PCI Boards
V CAUTION!
The actions described in this section may only be performed by
personnel with the appropriate technical training. Any unauthorized
openings and improper repairs could expose the user to risks
(electric shock, fire hazards) and could also damage the equipment.
Please observe the safety information in chapter Important Notes
on page 23.
In order to replace a hot-plug PCI board, the housing cover must be removed
as the slots are not directly accessible (see section Opening/Closing the
Housing on page 95).
V CAUTION!
The housing cover must be replaced as fast as possible due to cooling,
to comply with applicable EMC regulations (regulations on electromag-
netic compatibility) and to protect against fire. the maximum opening time
of the housing cover amounts to 15 minutes.
The failure of a hot-plug PCI board is notified on the corresponding slot on the
rear of the server (see table 5 on page 56).

Table of Contents

Other manuals for Fujitsu Primergy RX300 S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Primergy RX300 S3 and is the answer not in the manual?

Fujitsu Primergy RX300 S3 Specifications

General IconGeneral
Tcase78 °C
Bus typeFSB
FSB ParityYes
Processor cache4 MB
Processor cores2
Processor model5080
Processor seriesIntel Xeon 5000 Series
Processor socketLGA 771 (Socket J)
Processor threads4
Processor codenameDempsey
Motherboard chipsetIntel® 5000P
Processing Die size162 mm²
Processor frequency3.73 GHz
Processor cache typeL2
Processor lithography65 nm
Processor system typeDP
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1066 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)130 W
Processor core voltage (AC)1.25 - 1.40 V
CPU multiplier (bus/core ratio)14
Number of Processing Die Transistors376 M
Maximum graphics card memory8 MB
Memory slots8
Internal memory2 GB
Internal memory typeDDR2-SDRAM
Maximum internal memory32 GB
Memory layout (slots x size)2 x 1 GB
Networking featuresEthernet/Fast Ethernet/Gigabit Ethernet
Expansion slots1 x PCIe x8, 2 x PCIe x4, 2 x PCI-X
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Noise level56 dB
Chassis typeRack (2U)
Compatible operating systemsWindows Server 2003, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, VMware ESX
I/O ports8 x SAS
Power supply600 W
Power requirements100 - 240V, 50/60 Hz
Operating temperature (T-T)10 - 35 °C
SafetyIEC 60950-1, EN 60950-1
Electromagnetic compatibilityEN 55 022 A, EN 55024, EN 61000-3-2 / -3-3
RAID levels1, 5, 10, 50
Processor ARK ID27213
Weight and Dimensions IconWeight and Dimensions
Depth785 mm
Width483 mm
Height86 mm
Weight25000 g

Related product manuals