EasyManua.ls Logo

Fujitsu Primergy RX300 S3 - Adding a Hot-Plug Power Supply Unit; Replacing a Hot-Plug Power Supply Unit

Fujitsu Primergy RX300 S3
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76 Operating manual RX300 S3
Hot-plug Power Supply Units Hot-plug Components
8.1.2 Adding a hot-plug Power Supply Unit
Ê Insert the second power supply unit, lock it in the free location (see section
Replacing a Hot-plug Power Supply Unit) and connect it to the line voltage
(see section Connecting the Server to the Line Voltage on page 45).
8.1.3 Replacing a Hot-plug Power Supply Unit
Figure 18: Unlocking and removing the power supply unit
V CAUTION!
Before replacing a non defective power supply unit in a non-redundant
configuration (only one power supply unit present) the server must be
switched OFF.
Ê Remove the cable from the installed power supply unit.
Ê Push the transport look (green latch) in the direction of the arrow (1) and pull
the power supply unit out of the location (2).
Ê Insert the new power supply unit in the empty location until it engages.
I Make sure that the power supply unit engages correctly in the mounting
location and is locked in position.
This is the only way to avoid the power supply unit being shaken out of
its mountings and damaged during transport.
Ê Connect up the power supply unit.

Table of Contents

Other manuals for Fujitsu Primergy RX300 S3

Related product manuals