160
8.2 Electric wiring
8 Electrics/electronics
MITSUBISHI FUSO body/equipment mounting directives for FE Issue date: 20. 10. 2020
! Only print out complete sections from the current version
8.2.6 Grounding
Ground extended power cable to the circuit
connecting to the minus (–) terminal of battery. In the
case of grounding to the frame, establish the
grounding point on unmasked or uncoated surface.
Use eyelet terminal for grounding.
Dedicated bolt for grounding is used for tightening
ground terminal. In the case where dedicated
grounding bolt is removed during custom-built truck
body installation, do the following.
• If grounding point is not relocated
Reinstall the removed dedicated grounding bolt by
tightening to the specified torque.
• If grounding point is relocated
Use designated dedicated grounding bolt shown
below. Spot weld nut to the frame and tighten bolt
to the specified torque. Provide the weld with
touch-up coating.
When wiring from the custom-built truck body side is
grounded to the frame, do the same as described in [If
grounding point is relocated] above.
1 Identification mark
2 Ground terminal
3 Weld nut MF434105
4 Dedicated grounding bolt
Part no.: MK416036 (M10x30 P1.25)
Part no.: MK560984 (M10x35 P1.25)
Tightening torque: 39 - 40 Nm
5Chassis frame