<Functions of Model Menu (Helicopter Functions)>
Throttle limiter function
Setting method
*Set at the 3rd page of the throttle curve screen.
•Activate the function.
1.SelectACTandtouchtheRTNbutton.
2.SwitchthedisplaytoACTbyscrollingthe
touchsensor.
*Thedisplayblinks.
INH:Inhibit
ACT:Activate
3.EntertheselectionbytouchingtheRTN
button.
•ON/OFF switch setting
1.SelectSWandtouchtheRTNbutton.
2.TheH/WSETscreenisdisplayed.Selectthe
hardwareandtouchtheRTNbutton.
This function limits the high range of the throttle
movement by any slider or trimmer.
*Control which adjusts the limit point during ight can be set.
•High side operating range setting
1.SelectHIGHandtouchtheRTNbutton.
2.Adjustthehighsideoperatingrangeby
scrollingthetouchsensor.
*A gauge is displayed at the left side of the graph.
3.TouchtheRTNbuttontoswitchtothecursor
mode.
•Low side operating range setting
1.SelectLOWandtouchtheRTNbutton.
2.Adjustthelow sideoperatingrangeby
scrollingthetouchsensor.
*A gauge is displayed at the left side of the graph.
3.TouchtheRTNbuttontoswitchtothecursor
mode.
•Limiter operating range adjustment control
setting
1.SelectCTRLandtouchtheRTNbutton.
2.TheH/WSETscreenisdisplayed.Selectthe
hardwareandtouchtheRTNbutton.
*The throttle limiter operating position is indicated by a
dotted line on the graph.
*When limiter operating range adjustment control is NULL,
the throttle limiter function is not performed.
•Changing the control center position
1.SelectCENTERandtouchtheRTNbuttonfor
1second.CENTERchangesfromINHto“rate
display”.
2.WhentheCENTERrateischanged,the
neutralpositionof thehardwaresetatCTRL
canbeadjusted.
*When CENTER is INH, the neutral position becomes the
LOW intermediate value.
*When CENTER is changed from INH to “rate display”, the
CENTER rate is set to the LOW intermediate value.
*The CENTER rate can be set between HIGH and LOW.
[Throttlelimitersetting]
When"CTRL"issetasa"RS"sideslider.
Thestateoffullhighofathrottlestick.
“RS”Position
Throttle
Position
Full
RestrictionRestrictionRestriction
Slow
Full
Slow
Full
Slow
In"INH",thehalfway
pointof"HIGH"and
"LOW".
HIGH
LOW
CENTER
SB