8G093X01 R5
VR Programming Guide
August 2022 Page 106 of 144
Field Name
Range
Description
Notes
Send Emergency
Ack. Tones
Enable / Disable
Check box
Enables / Disables the Emergency
Ack Tones sent by the VR to
Analog PSUs.
Affects Analog Mode only.
All Tones sent by the VR
in Analog Mode are heard
by all PSUs tuned to the
same VR Channel, which
PSUs are within the VR
radio coverage area.
Portable Ack
Required
Enable / Disable
Check box
Enables / Disables the Emergency
Ack signaling sent by the VR to
the PSU when the VR receives a
PSU Emergency Alarm.
Default setting is Enabled.
Attempts Timeout
30 to 255 (30) s
After decoding an Emergency
request from a PSU, a Secondary
VR waits for the duration of this
timer and if no other emergency
request is received from the PSU,
the counter will be cleared. If
another emergency request is
received, the VR will increment the
counter accordingly refer to the
Attempts Counter Setting.
Attempts Counter
0 to 10 (4)
Determines the number of PSU
Emergency attempts a Secondary
VR will need to detect before it
switches to Primary System Mode
and processes the Emergency to
the System. This counter is reset
when the VR sends an Ack to the
PSU or when the Attempts
Timeout timer expires.
When set to 0 the
Secondary VR will not
monitor if the PSU
Emergency is being
serviced by a Primary VR
or not.
ANI 5 Tone Types
EEA
CCIR
EIA
Determines the ANI 5-Tone Type.
Must match the Analog PSU
programming.
Affects Analog Mode only.
FG Emergency
Destination
Local
System
Both
Determines the routing of
Emergency message received by
the VR from a Local PSU on a FG
enabled VR channel.
Applicable to VR channels
which have FG signaling
enabled.