8G093X01 R5
VR Programming Guide
August 2022 Page 107 of 144
Block Emergency
Call State
YES - While in Emergency Call
State, if 'Block Emergency Call
State' is set to 'YES', VR would
forward all calls received from the
analog PSUs without leading PTT
ID as regular calls and not
emergency calls.
NO - While in Emergency Call
State, if 'Block Emergency Call
State' is set to 'NO', VR would
forward all calls received from the
analog PSUs without leading PTT
ID as emergency calls.
Applicable to Analog VR
mode and analog PSUs
only.
If emergency alarm or call
was declared by an analog
PSU, the VR enters
Emergency Call State and
remains in this state until
all the MDC PSU
emergencies are cancelled
by the PSU or VR.
The VR Emergency Call
State is cancelled by
pressing the DVRS button,
by preprogrammed
emergency cancel timer or
remotely via Emergency
Cancel ANI code.
Disable
ANI 5 to Tones
DTMF
If enabled, the VR will clear the
emergency upon detection of the
programmed Emergency Cancel
Code.
Affects Analog Mode only.
This field specifies the Emergency
Cancel ANI / DTMF Code
sequence. Must match the Analog
PSU programming.
Affects Analog Mode only.
Applicable only if the
Emergency Cancel
Signaling Type Field is
Enabled.
The PSU must be
programmed with * as the
last DTMF sign, for
example 456*.
If programmed, the VR will
automatically clear the emergency
upon expiration of the
programmed timer.
VR Emergency
Echo Ack Enabled
Enable / Disable
Check box
If enabled, the VR proxies the FNE
Ack first to the PSU to prevent
further emergency retries while the
console Ack is being processed.
If disabled, the PSU continues
emergency retries until it receives
the console ack.
Should be disabled when generic
PSUs are in use because they are
unable to differentiate between
FNE and Console
acknowledgements.
Applicable when Mobile
Radio Channel Setup →
Emergency Ack. Type is
set for Console Ack and
PSU is configured for
Console Ack Required
(DVRS) (APX CPS,
Emergency Config. →
Conventional Emergency
Profile)