8G093X01 R5
VR Programming Guide
August 2022 Page 114 of 144
Table 7: Analog Group Call Handling when Mixed Mode Hold Timer Running
Table 8 - Mode Change Handling
Allowed VR Modes
VR Channel Config
VR Mode
Allowance Rules
User
Local
Local-
Fixed
System
System-
Fixed
MSU
Channel
Config
Off
OSL
OSL
OSL
OSL
OSL
All modes allowed
Local
OSL
OSL
OSL
OSL
OSL
All modes allowed
System
OSL
OSL
OSL
OSL
OSL
All modes allowed
Local-
Fixed
OL
OL
OL
OL
OL
LOCAL / OFF only
System-
Fixed
OS
OS
OS
OS
OS
SYSTEM/OFF only
None
OSL
OSL
OL
OSL
OS
Follow VR
Channel
restrictions
User
OSL
OSL
OSL
OSL
OSL
All modes allowed
Disabled
D
D
D
D
D
Always DISABLED
(O=OFF, S=SYSTEM, L=LOCAL, D=DISABLED)
Summary of “Display PSU Duplicate ID” warning functionality:
If Duplicate PSU ID is detected, VR displays warning message on Control Head’s VR line
(top line)
Message is displayed in the following format is DUPL: PsuIdNumber (for example DUPL:
3565)
Duplicate ID warning Message is alternating with primary display messages at the same
rate as other VR warning messages (2 seconds for warning / 6 seconds of primary
message)
VR would “remember” and alternate up to 10 different duplicate IDs
Duplicate IDs warning will remain alternating on display until VR is powered down /
restarted
VR keeps the warning even after VR is deactivated (VR mode is changed to OFF). This
allows user to drive back to the station and report duplicate ID incident to communication
personnel.
PSU TG in TG
Translation Table
VR Common
Setup Block
Fallback to
Local Repeat
Result
Yes
N/A
Voice repeated locally and sent to MSU
No
Unchecked
Voice repeated locally
Checked
Call is denied. User must wait until timer expires to
make a PSU call.