8G093X01 R5
VR Programming Guide
August 2022 Page 81 of 144
Field Name
Range
Description
Notes
Emergency
Rev.Item#
Item # (on
the same
screen)
The correct Emergency
Revert MSU Mode
referenced by its Item #
must be programmed
to indicate which mode
the MSU must revert to
and issue the PSU
emergency on.
Important: Specifying
an incorrect Item # in
this field may result
in the loss of
Emergency and
subsequent
Emergency
communications!
Entering ‘0’ in this
field is equivalent to
‘No revert’.
Applicable to non-proxied P25 PSU operation
(such as during TG translation), analog PSU or
Forced Analog / Forced Analog All PSU operation
when the selected MSU mode is Type 2 Trunked or
P25 Trunked (FDMA or TDMA).
This field will be marked red (invalid) if it:
Points to zone entry
Points to MSU channel, which has ‘TG Mode’
programmed as "Disabled"
Points to value that is greater than Num. of
Items
Points to an MSU channel, which does not
have proper set of VR channels in the list of
allowed VR channels (Emergency Revert MSU
channel must have all VR channels that the
originating MSU channel has)
Emergency
Ack. Type
1. ‘VR Ack
1. VR sends Ack to
PSU after MSU has
transmitted alert to
the FNE. If MSU is
unable to transmit
this emergency
alert for any
reason, VR will not
send an Ack to the
PSU.
1. Typically used when DVRS is deployed in a
conventional setup without a console to
acknowledge user’s emergency.
2. ‘Site Ack
2. VR proxies
Emergency Alert
through the MSU to
the site and proxies
the site
acknowledgement
to the local PSU.
2. Typically used when the DVRS is deployed in
a trunking setup.

Table of Contents