3. Typically used when DVRS is deployed in a
trunking setup. Requires:
• Emergency Setup→VR Emergency Echo
Ack to be checked.
• PSU CPS: Emergency
Config.→Conventional Emergency Profile
→Console Ack Required (DVRS) to be
enabled.
When enabled, DVRS will proxy both FNE and
Console acknowledgements to the PSU.
When disabled, the DVRS will only proxy the
Console acknowledgement to the PSU.
If enabled the DVR will proxy the FNE Ack first to
the PSU to prevent further emergency retries
while the console ack is being processed. If
disabled, the PSU will continue emergency
retries until it receives the console ack.
Should be disabled when generic PSUs are in
use because they are unable to differentiate
between FNE and Console
acknowledgements.
4. Typically used on system analog conventional
channels when MSU is unable to transmit
emergency signaling (e.g.: non-ASTRO
signaling type set to ‘None’).
When MSU channel type is analog or Type II, this
field applies only to:
• Analog PSU using Analog or Mixed VR
channels
• Enhanced PSU using Mixed or Forced Analog
VR channels.
Exceptions when enabled:
• Analog Conventional System: MSU ID sent
when local PSU ID size exceeds limit
• Type II Trunking System: MSU ID sent for calls
(PTT/Emer PTT); Local PSU ID sent only for
Emer Alert; MSU ID sent when local PSU ID
size exceeds limit
• See notes in Analog Setup → MDC PTT ID
Offset