PanaFlow™ LC User’s Manual 75
Chapter 4. Error Codes and Troubleshooting
After you have tried eliminating/correcting for any most likely causes mentioned above, if error still exists,
also check:
1. Incorrect programming on Error Limits or flow condition changes that now make previous programming
invalid.
2. Defective/Damaged cables, transducers, incorrect physical spacing, couplant, buffer or electronics.
In case you are unable to clear the errors, collect diagnostic data and parameter information for each
channel in the Diagnostics Data Table prior to calling your local sales or service center.\
4.3.1c Viewing Channel Specific Error/Warnings
To indicate the health of the meter, PanaFlow™ LC has built-in Error codes. The Channel specific errors are
very critical in determining the corrective actions required. Figure 80 below shows the steps to view current
channel specific errors/warnings. The description of the Error Codes and the recommended actions are
provided in Table 21 below.
Figure 80: Viewing Current Channel Specific Errors
9
2
2
9
9
Composite Flow Info
E23: MultiChAccuracy
2
Velocity
0.000
m/s
Display Format
Program
Flow Info
Ch 1 Flow Info
Ch 2 Flow Info
Ch 3 Flow Info
CH1 E1: SNR Error!
CH2 E1: SNR Error!
CH3 E1: SNR Error!