EasyManua.ls Logo

GE RSDetection RS-S131-200-ER0000 - Page 90

GE RSDetection RS-S131-200-ER0000
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RSDetection
User’s Manual
March 2016 S131-200-UM Rev A
Page 76
g
Command
Support
Comments
TTTT Start Time.
EEEE End date.
UUUU End Time.
IDs of Sensor for N
0 Wind Speed
1 Null
2 Barometric Pressure (psia)
3 Wind Direction (°)
4 Dose Rate (mR/h)
5 High Voltage (V)
6 Battery Voltage (V)
7- Temperature (°C)
8 Rain Accumulator (unit defined by definition)
Note that it is assumed each point has been recorded at the
time interval indicated by the first returned line of a data set. If
a gap is detected a new data interval and new time stamp will
be generated.
Sample Output
00:00:08 //;8 seconds between points
05/29/98 14:22:33 //Time stamp
.0079 .0068 .0078 .0079 .0077 .0084 .0074 .0083 .0076 .0070
00129
.0075 .0077 .0074 .0079 .0078 .0072 .0076 .0080 .0073 .0073
00118
.0073 .0079 .0074 .0070 .0073 .0071 .0084 .0083 00085
00:00:10 //;10 seconds between points
05/29/98 14:28:50 // Time stamp after gap
.0066 .0078 .0077 .0087 .0082 .0073 .0078 .0067 .0076 .0068
00131
.0069 .0074 .0080 .0070 .0079 .0079 .0077 .0076 .0075 .0069
00127
.0076 .0080 .0075 00033