EasyManua.ls Logo

GE Transport PT878 - Entering the Pipe Parameters

GE Transport PT878
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
August 2008
2-4 Initial Setup
Special Transducers
(cont.)
5. Use the [T] key to reach the Wedge Tmp prompt and press
[ENTER]. Use the numeric keys to enter the wedge temperature
value provided with your transducer. Press [ENTER] to confirm
your entry.
6. Use the [T] key to reach the Wedge SS prompt and press [ENTER].
Use the numeric keys to enter the wedge sound speed (in ft/sec or
m/sec) value provided with your transducer. Press [ENTER] to
confirm your entry.
7. Press [F3] (OK) to confirm your selections and exit the Program
Menu. Otherwise, you can press [F2] (Cancel) or the [ESC] key to
exit the Program Menu without confirming your selections.
Proceed to the next section to enter your pipe parameters.
Entering the Pipe
Parameters
To program your pipe parameters, scroll to the Pipe option on the
Program Menu (see Figure 2-3 below) and press [ENTER].
Note: Refer to Sound Speeds and Pipe Size Data (914-004) for
additional information about pipe sizes and sound speeds.
Figure 2-3: The Pipe Option Window
1. At the Material prompt, press [ENTER] to open a list of options (see
Table 3-1 on the next page). Use the [T] or [S] keys to scroll to
your material or choose “Other” if your material is not on the list.
Transducer
Lining
Path
Transducer/Pipe
Pipe Fluid
Cancel
OK
Material
Other
Sound Speed
600.3
m/s
5
ANSI
OD, mm
Wall, mm
2
Nominal Schedule
OD x PI, mm
15.708
Measure Wall with TGauge