6. SpeedReferenceCommandConguration
The inverter offers users several choices to set the speed reference source. The most commonly used meth-
ods are described in the next sections.
Frequency reference command is selected with parameter 00-05.
00-05:MainFrequencyCommand(FrequencySource)
This function sets the frequency command source.
Setting Range: 0 to 5
To set parameter 00-05:
- After power-up press the DSP/FUN key
- Set Group 00 (Basic Fun), and select parameter -05 with the UP/DOWN ▲ and ▼ keys and press the
READ/ ENTER key.
Code Parameter Name / Range
00-05 Main Frequency Command Source Selection
0: Keypad
1: External control (analog)
2: Terminal command UP / DOWN
3: Communication control (RS-485)
4: Pulse input
5: Reserved
6: Reserved
7: AI2 Auxiliary Frequency
6.1. Reference from Keypad
LED Keypad (KB-LED-VDI100):
Use the </RESET, ▲ and ▼ keys to change the speed reference and then press the READ/ENTER key. Refer
to section 4.1.5 for more details.
LCD Keypad (KB-LCD-VDI100):
Press the READ/ENTER key rst and use the </RESET, ▲ and ▼ keys to change the speed reference.
6.2. ReferencefromExternalAnalogSignal(0-10V/4-20mA)
AnalogReference:0–10V(Setting00-05=1)
E
DO2
24VG
S2 S4 S6 S8 24V +12V GND AI1 AI2
DO1 DOG S1 S3 S5 S7 F1 F2 PI AO1 AO2
E
Connect shield to
control ground terminal
0 – 10 V
+
-
Analog
Input AI1
Common/0V, GND
Control Terminals /
User Terminals
VDI100 • Instruction manual 311

Table of Contents

Questions and Answers:

gefran VDI100 Series Specifications

General IconGeneral
Brandgefran
ModelVDI100 Series
CategoryInverter
LanguageEnglish

Summary

1. Safety Precautions

1.2. Before Supplying Power to the Inverter

Ensures correct wiring and warns against connecting input supply to output terminals.

1.3. Wiring / Câblage

Details proper grounding, RCD compliance, and dielectric withstand test precautions.

1.4. Before Operation

Covers model matching, carrier frequency adjustment for long cables, and cover installation.

1.6. Operation / Opération

Provides guidelines for safe inverter operation, including cover installation, motor connection, and fan operation.

1.7. Maintenance, Inspection and Replacement

Details procedures for maintenance, inspection, and replacement, emphasizing safety precautions.

2. Model Description

2.1. Nameplate Data

Essential for verifying inverter nameplate and ensuring correct rating for application.

2.2. Inverter Models – Motor Power Rating (HD – Heavy Duty)

Lists inverter models and their corresponding applied motor power ratings for Heavy Duty applications.

3. Environment and Installation

3.1. Environment

Specifies operating temperature, storage, humidity, altitude, installation site, and shock conditions.

3.2. Installation

Details inverter installation in an upright position and required surrounding space for heat dissipation.

3.3. External View

Illustrates the external appearance of different inverter sizes, labeling key components.

3.4. Warning Labels

Highlights important warning information located on the front cover that must be read upon installation.

3.5. Removing the Front Cover and Keypad

Explains how to remove the front cover to access terminals for wiring connections.

3.6. Wire Gauges and Tightening Torque

Provides UL approved wire gauges, crimp terminals, and fastening torque specifications.

3.8. General Wiring Diagram

Illustrates the basic power and control circuit terminal connections for the inverter.

3.10. Power Terminals

Specifies terminal connections for input power, inverter output, and ground.

3.12. Inverter Wiring

Provides wiring precautions, power input terminal details, and grounding requirements.

4. Keypad and Programming Functions

4.1. LED Keypad (KB-LED-VDI100)

Details the LED keypad display, its keys, and their functions for inverter operation and parameter setting.

4.2. LCD Keypad (KB-LCD-VDI100)

Explains the LCD keypad display, its keys, and the menu structure for programming and monitoring.

4.3. Parameters

Provides a comprehensive list of all inverter parameters categorized into groups for easy access and configuration.

Related product manuals