EasyManua.ls Logo

gefran VDI100 Series

gefran VDI100 Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.6. ChangeFrequencyUnitfromHztorpm
Enter the number of motor poles in 16-03 to change the display units from Hz to rpm.
Code Parameter Name / Range
16-03 Display unit
0: Display unit is Hz (Resolution is 0.01Hz)
1: Display unit is % (Resolution is 0.01%)
2: Frequency display unit is rpm
3~39: Display unit rpm, (uses number of motor poles to calculate)
40~9999: 100% is XXXX with no decimals (integer only)
10001~19999: 100% is XXX.X with 1 decimal
20001~29999: 100% is XX.XX with 2 decimals
30001~39999: 100% is X.XXX with 3 decimals
Example: Motor poles 4, 16-03 = 4.