GFA TS981 - Connecting External Devices

GFA TS981
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
L1
L2
L3
PE
L1
L2
L3
PE
L
PE
N
L
PE
N
SI 25.15 WS,
=
SI 45.7 WS
3
-
phase with neutral
3~, N, PE
220–400 V / 50-60 Hz
3
-
phase without neutral
3~, PE
220–400 V / 50-60 Hz
1
-
phase symmetrical
1~, N, PE, sym.
220– 230V / 50-60 Hz
1
-
phase asymmetrical
1~, N, PE, asymmetrical
220–230 V / 50-60 Hz
NOTICE
Damage due to moisture or penetrating foreign bodies
Check that all cable glands are tight.
Seal open and unused cable entries with blanking plugs. This will prevent moisture or foreign bodies such
as insects from penetrating.
7 Connecting external devices
WARNING
Danger to life from electric shock!
Improper wiring may result in severe or fatal injury from electrical current.
Allow only qualified electricians to carry out the work.
Disconnect all cables from the power supply.
Secure the mains disconnector against plugging in or switching it on again.
Observe valid regulations and standards.
Use suitable tools.
Check the insulation of cables and make sure that cables outdoors ar
e protected.
i
NOTE
The inputs of the following safety devices of the control are rated Performance Level c (PLc):
Slack-rope switch
Pass-door switch
Safety edge
Limit switch system
Safety circuit of the drive unit
Emergency STOP control device
i
NOTE
Connect only sensors that comply with the current EN
12453 and are suitable for
Performance Level c.