Instruction Manual ProfiLux 4 / 4e
EN 2019-01-22 43
When loading sensor data, the serial number is also checked. If these are not identical, only the
controller settings, but not the calibration data, can be loaded. This prevents accidental calibration
data from another device being loaded. The remaining sensor data can be loaded.
Basically, all settings found in the file are transferred to the connected aquarium computer.
If only some of the settings should be transferred, the file can be edited accordingly. The
lines in the file containing entries with settings that are not to be transferred may be deleted
via a text editor for example.
6.6 Measurement Data
ProfiLux 4 / 4e is able to record measurement data.
With Read & Save, all new existing measurement data is read out of the ProfiLux and is
written into a text-file. ProfiLux 4 stores the time of the recording so that the same data is not
collected several times. Before saving you have the possibility to set some formats for the
data export. The standard settings are well suited to import the file later easily in Microsoft
Excel®.
If you select an already existing file for saving, the new data will be attached to the already
existing data, as far as the existing file contains suitable information. This text file can then
be used with e.g. Microsoft Excel® to process the data.
7 Expansion Modules
7.1 General Information
ProfiLux4 / 4e is modular and can be expanded as such. In order to use additional sensors,
power strips, dimmable lamps etc., you must first install the appropriate ProfiLux Expansion
Card; up to 3 additional ProfiLux Expansion Cards can be added.
Before adding ProfiLux Expansion Cards to the ProfiLux 4 / 4e, a firmware update may be
required. Please follow the accompanying notes of the Expansion Cards to check if an update
is required.
Firmware 7.02 supports the following expansion cards: