Troubleshooting
EOF 10-10/20
7-01. Temperature Control System - Continued
Problem Probable Cause Corrective Action
FRYER HEATING SLOWLY:
Slow recovery
Heat Light staying ON continuously
A. Incorrect cooking procedures Consult Operation Manual for proper
procedures
B. Heating element failing Replace faulty element
C. Contactor failing Replace faulty contactor
D. Loose wiring in heat control circuit Inspect and repair wiring
E. Faulty power switch Replace power switch
F. Low power supply voltage Correct power supply
FRYER HEATS SLOWLY:
Short Cycling; Heat Light CONTINU-
OUSLY cycling ON & OFF
A. Low power supply voltage Correct power supply
B. Variable temperature sensor too
close to heating element
Reposition senor to proper location
C. Faulty cooking Controller Replace Controller
ERRATIC OIL TEMPERATURE: A. Faulty temperature sensor Replace Sensor probe
B. Contactor failing Replace faulty contactor
C. Faulty cooking Controller Replace Controller
D. Loose wiring in heat control circuit Inspect and repair wiring
OIL SMOKING: A. Oil is old, used too long Boil-out vat, fill with fresh oil
B. Cooking temperature too high Check temperature setting, adjust
C. Heating elements are dirty Clean vat (boil-out), scrub elements
with provided brushes
D. Faulty heating element Replace faulty element
E. Improper voltage for elements
installed in unit
Supply proper voltage power to unit
F. Oil level is LOW Keep oil at FULL level (without prod-
uct)