74
DESCRIPTION OF THE CODED MODULE
Description of the N3301/AL - NX3301 coded module:
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
Front.
Back.
Green LED.
Red LED.
Numeric keypad.
Key button.
Cancel button.
Sw1 DIP switch.
Jp1 tamper jumper.
Nexa BUS connectors.
Connection block.
: Power input (Do not power when connecting the Nexa Bus link hose.
See p. 68 for connections)
: Normally open output relay 1.
: Common relay 1.
: Normally closed output relay 1.
: Normally open output relay 2.
: Common relay .2
: Normally closed output relay 2.
: Panic output.
: Negative.
: Input for exterior button relay 1.
: Input for exterior button relay 2.
~ ~
NA1
C1
NC1
NA2
C2
NC2
P
-
PL1
PL2