128
Float Voltage
When the battery is approaching full charge, it will switch to float charging
mode. This value is the upper limit of charging voltage in this mode. Please
set it according to the battery technical parameters.
The Time Float Charging
When the battery charging status changes from constant charging to float
charging, and the duration reaches the set value, the battery charging
mode will switch to float charging mode. The default duration is 180s.
Constant Charging Voltage
The battery charging mode is set to constant voltage charging by default;
this value is the upper limit of charging voltage in this mode. Please set it
according to the battery technical parameters.
Maximum Current For
Switch To Float Charge
The maximum charging current in the floating charge state. Please set it
according to the battery technical parameters.
When the battery is nearly fully charged, it will enter the floating charge
state. Please refer to the technical parameters of the corresponding battery
model for specific definitions.
Setting Working Mode