145
5
Maximum
Discharging Current
Please set it according to the battery technical
parameters. The greater the discharge current is,
the shorter the working time of the battery is.
6
Maximum Charging
Current
The maximum current during charging, used to
limit the charging current. Please set it
according to the battery technical parameters.
7
Float Voltage
When the battery is approaching full charge, it
will switch to float charging mode. This value is
the upper limit of charging voltage in this mode.
Please set it according to the battery
technical parameters.
8
The Time Float
Charging
When the battery charging status changes from
constant charging to float charging, and the
duration reaches the set value, the battery
charging mode will switch to float charging
mode. The default duration is 180s.
9
Constant Charging
Voltage
The battery charging mode is set to constant
voltage charging by default; this value is the
upper limit of charging voltage in this mode.
Please set it according to the battery
technical parameters.
10
Maximum Current
For Switching To
Float Charge
The maximum charging current in the floating charge
state. Please set it according to the battery technical
parameters.
When the battery is nearly fully charged, it will enter
the floating charge state. Please refer to the technical
parameters of the corresponding battery model for
specific definitions.
9.4.5 Setting Generator Parameters
This function supports settings through the SolarGo app or LCD screen.
Method I: Setting via SolarGo APP
Step 1: After connecting to the SolarGo APP, go to Home > Settings > Port Connection >
Generator Connection. After selecting the generator type, enter the parameter setting