Green light flashes 3 time/s
The PCS communication is lost
Green light slowly flashes
After the battery system gives an
alarm, it will conduct a self-check and
wait until the self-check is over, then it
will change to normal working status
or fault status.
ALM Light
Red light steady on
Check both the button indicator and
the SOC indicator status to determine
the fault that has occurred and handle
the problem follow the methods
recommended in the Troubleshooting
section.
7.3.3 Smart Meter Indicator
GMK110
Type
Status
Description
Power indicator light
Steady on
The smart meter is power on.
Off
The smart meter has been powered off.
Communication
indicator
Blinks
Meter communication is normal
Off
Meter communication is abnormal or has no
communication
GM330
Type
Status
Description
Power indicator light
Steady on
Power on, no RS485 communication.
Blinks
Power on, RS485 communication works
properly.
Off
The smart meter has been powered off.
Communication
Off
Reserved