205
*2 The system's working current and power values will be related to temperature and State of
Charge (SOC).
*3 Max charge / discharge current values may be variant with different inverter models.
12.3 Smart Meter Technical Data
Technical Parameters
GMK110
Application
Single phase
Input Data
Voltage
Nominal Voltage (V)
220
Voltage Range (V)
85~288
Nominal Voltage
Frequency (Hz)
50/60
Current
CT Ratio
120A/40mA
CT Quantity
1
Communication
RS485
Communication distance (m)
1000
User Interface
2LED
Accuracy
Voltage/Current
Class I
Active Energy
Class I
Reactive Energy
Class II
Power Consumption (w)
5
Mechanical
Parameters
Dimensions (W x H x D mm)
19*85*67
Weight (g)
50
Mounting Method
Rail Installation
Environmental
Parameters
Ingress Protection Rating
IP20
Operating Temperature Range (℃)
-30 ~ 60
Storage Temperature Range (℃)
-30 ~ 60
Relative Humidity (Non-Condensing)
0~95%
Max. Operating Altitude (m)
3000