137
Step 2: Enable or disable the power limit function based on actual needs.
Step 3: Enter the parameters and tap √. The parameters are set successfully.
Number
Parameter
Description
1
Power Limit
Enable Power Limit when power limiting is required
by local grid standards and requirements.
2
Export Power
Set the value based on the actual maximum power
feed into the utility grid.
3
External CT Ratio
Set the ratio of the primary current to the
secondary current of the external CT.
Method II: Setting via LCD
Step 1: Click on the screen or select the settings icon >System Setup>Quick
Setting>Power Limit through the button to enter the settings page.
Step 2: Set up the function according to actual needs.
Number
Parameter
Description
1
Power Limit
Enable Power Limit when power limiting is required
by local grid standards and requirements.
2
Export Power
Set the value based on the actual maximum power
feed into the utility grid.
3
External CT Ratio
Set the ratio of the primary current to the

Table of Contents