Step 1: Click on the screen or select the settings icon >System Setup>Advanced
Function through the button to enter the settings page. (Advanced Function initial
password: 123456)
Step 2: Set the function based on actual needs.
In off-grid mode, the switch controls the on/off of
the inverter's off-grid function. In on-grid mode,
this function does not take effect.
The switch is initially in the ON state, and the off-
grid function is enabled. After the inverter is
powered on, the inverter has the off-grid output
ability. In the off-grid state, turning off and then
turning on the off-grid switch, the off-grid overload
time can be cleared and the off-grid output can be
restarted.
9.4.3 Setting Power Limit Parameters
This function supports settings through the SolarGo app or LCD screen.
Method I: Setting via SolarGo APP
Step 1 Tap Home > Settings> Advanced Settings > Power Limit to set the parameters.