9.5 Setting Safety Parameters
This function supports settings through the SolarGo APP only.
9.5.1 Setting the Basic Safety Parameters
The grid standards of some countries/regions require that inverters shall set
functions to meet local requirements.
Step 1: Tap Home > Settings > Advanced Settings, to set the parameters.
Enable DRED/Remote Shutdown/RCR before
connecting the third party DRED, remote
shutdown, or RCR device to comply with local
laws and regulations.
Three-phase
Unbalanced Output
Enable Three-phase Unbalanced Output when
the utility grid company adopts phase separate
billing.
Backup N and PE Relay
Switch
To comply with local laws and regulations, ensure
that the relay inside the back-up port remains
closed and the N and PE wires are connected
when the inverter is working off-grid.
Enable AUTO TEST to set auto test for grid tying
in compliance with local grid standards and
requirements.
9.5.2 Setting Customized Safety Parameters
Set the custom safety parameters in compliance with local requirements. Do not