EasyManua.ls Logo

Goodwe GW10K-ES-C10 - Battery Technical Data

Goodwe GW10K-ES-C10
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
199
12.2 Battery Technical Data
LX A5.0-10
Technical Parameters
LX A5.0-10
2*LX A5.0-10
n*LX A5.0-10
usable energy (kWh)
* 1
5
10
n×5
Battery Module
LX A5.0-1051.2V 5.0kWh
Number of Modules
1
2
n
Cell Type
LFPLiFePO
4
Nominal Voltage (V)
51.2
Operating Voltage Range (V)
47.5~57.6
Nominal Charge/Discharge Current
(A)
*2
60
120
n×60
*3
Nominal Charge/Discharge Power
(kW)
*2
3
6
n×3
*3
Operating Temperature Range (℃)
Charge: 0 ~ +50; Discharge: -10 ~ +50
Relative Humidity
0~95%
Max. Operating Altitude (m)
3000
Communication
CAN
Weight (Kg)
40
80
40
Dimensions (W x H x D mm)
Single LX A5.0-10 module: 442×133×420 (without
handle); 483×133×452 (with handle)
Ingress Protection Rating
IP21
Storage Temperature (℃)
0 ~ +35 (≤ 1 year); -20 ~ 0 (≤ 1 month); -40 ~ 45 (≤
1 month)
Mounting Method
Rack mounted/Ground mounted
Round-trip Efficiency
95%
Standard and
Certification
Safety
IEC62619IEC 63056IEC62040-1INmetro
EMC
EN IEC61000-6-1EN IEC61000-6-2EN IEC61000-
6-3EN IEC61000-6-4
Transportation
UN38.3ADR

Table of Contents

Related product manuals