*1: Test conditions, 100% DOD, 0.2℃ charge & discharge at +25±2 °C for battery system at
beginning life. System Usable Energy may vary with different Inverter.
*2: The nominal charge and discharge current and power are affected by temperature and
SOC status.
*3: Under the condition of using busbar box to achieve parallel connection of batteries.
*4: New battery, within the range of 2.5~3.65V, at the temperature range of 25+2℃, under
the condition of 0.2C/0.2C charge and discharge. The efficiency is 94%~95% under the
charging and discharging condition of 0.6C/0.6C.
n:n≤15。
LX A5.0-30
Operating Voltage Range (V)
Nominal Charge Current (A)
*3
Max. Continuous Charge Current (A)
*2*3
Nominal Discharge Current (A)
*3
Max. Continuous Discharge Current (A)
*2*3
Max. Pulse Discharge Current (A)
Max. Continuous Discharge Power (W)
0<T≤40℃ (Recommended 10<T≤30℃)
Operating Temperature Range (℃)
Charge: 0<T≤55℃; Discharge: -20<T≤55℃
12 Months (maintenance-free)
Maximum Operating Altitude (m)
Dimensions (W x H x D mm)
442*133*520 (core part), 483*133*559 (max.
dimensions)
Ingress Protection Rating