The battery stop charging once the battery SOC reaches Charge Cut-off
SOC.
To set the stop SOC for battery discharge, please refer to section 9.4.4
on setting battery parameters and set the Depth of Discharge (On
Grid) and Depth of Discharge (Off Grid) through the LCD screen.
9.3 Communication Settings
Communication settings can only be set through SolarGo APP.
The communication configuration interface may vary depending on the type of
smart dongle connected to the inverter. Please refer to the actual interface for
accurate information.
Step 1: Enter the setting page through "Home" > "Settings" > "Communication
Configuration" > "Network Settings".
Step 2: Configure the WLAN or LAN network based on the actual situation.
Applicable to WLAN. Please select the corresponding network
based on your actual situation and communicate the device
with the router or switch.
Applicable to WLAN. Enter the password for the network you
actually selected.
When the router is using the dynamic IP mode, turn on the
DHCP function.
When using the router in static IP mode or using a switch,
turn off the DHCP function.
When DHCP is enabled, there is no need to configure this
parameter.
When DHCP is turned off, please configure this parameter