153
Number
Parameter
Description
1
Fix Q
Enable Fix Q when it is required by local grid standards
and requirements.
2
Under-excited
Set the reactive power as inductive or capacitive
reactive power based on actual needs and local grid
standards and requirements.
3
Over excitation
4
Power Factor
The percentage of reactive output power to apparent
power.
Setting the Q(U) Curve
Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings >
Reactive Power Mode to set the parameters.
Step 2: Enter the parameters. The inverter will adjust the reactive power to the apparent
power ratio in real-time according to the actual grid voltage to the rated voltage ratio.
Setting the Cosφ Curve
Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings >
Reactive Power Mode to set the parameters.
Step 2: Enter the parameters. The inverter will adjust the active output power to the
apparent power ratio in real-time according to the actual grid voltage to the rated voltage
ratio.