194
Charging Current (A)
Max. Continuous
Discharging Current (A)
*1
160176 at
10min
200220 at
10min
240264 at 10min
Maximum Charge power
(W)
8,000
10,000
12,000
Maximum Discharge
Power (W)
8,800
11,000
13,200
PV Input Data
Maximum Input power
(W)
*2
16,000
20,000
24,000
Max. Input Voltage (V)
600
600
600
MPPT Operating Voltage
Range (V)
60~550
60~550
60~550
MPPT Voltage Range at
Nominal Power (V)
180~500
170~500
200~500
Start-up Voltage (V)
58
58
58
Nominal Input Voltage (V)
360
360
360
Max. Input Current per
MPPT (A)
*4
32/16
32/32
32/32
Max. Short Circuit Current
per MPPT (A)
48/24
48/48
48/48
Max. Backfeed Current to
The Array (A)
0
0
0
Number of MPPT
2
2
3
Number of Strings per
MPPT
2/2
2/2
2/2
AC Output Data (On-grid)
Nominal Apparent
Power Output to Utility
Grid (VA)
8,000
10,000
12,000
Max. Apparent Power
8,800
11,000
13,200