EasyManua.ls Logo

GRAPHTEC CE5000-120AP - 4.14 Setting the Cutting;Plotting Area

GRAPHTEC CE5000-120AP
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-18
Function Settings and Operations
4.14 Setting the Cutting/Plotting Area
This function allows the area in which cutting/plotting will be performed to be specified, thereby preventing
cutting/plotting outside the specified area. This function enables more efficient use of the medium through the
specification of uncut portions of a medium that have already been cut, to avoid the previously cut areas.
Note that setting of the cutting/plotting area also repositions the origin point in accordance with the
movement of the cutting area.
Lower-left setting position
Upper-right
setting
position
Cutting/plotting in this area only
Y
X
(1) Press the (PAUSE) key to switch to PAUSE mode.
(2) Press the (NEXT) or (PREV.) key until the following menu is displayed.
ADVANCED FUNC.
(3) Press the (ENTER) key, and then press the (NEXT) or (PREV.) key
until the following menu is displayed.
PLOT AREA
(4) Press the (ENTER) key to display the plotting-area menu.
LL 0, 0
(5) Use the , , , and (POSITION) keys to move the pen to the lower-left
setting position, and then press the (ENTER) key. The coordinates of the
lower-left position set are displayed. To make the default setting, press the
(ORIGIN) key.
(6) Once the lower-left position has been set, the coordinates for the upper-right
position are displayed. Set these coordinates in the same way as for the lower-left
position.
(7) Press the (PAUSE) key to cancel PAUSE mode.
CHECKPOINT
The following message is displayed if the lower-left and upper-right settings are not
separated by a distance of at least 5 mm. If this message appears, reset the lower-left
and upper-right positions.
WRONG PLOT AREA
BLADE WARE SETUP
CUT LINE PAT.
TANGENTIAL
INIT. B
PEN UP SPEED
INITIAL FEED
AUTO PRE FEED
SETUP MENU
TEST
FEED&CUT
PEN UP/DOWN
ADVANCED FUNC.
CLEAR BUFFER