GREE U-Match 5 SERIES UNIT SERVICE MANUAL
148
Removal of air guide louver
Note: Before removal, make sure power is cut off. During the removal procedure, take goo
d care of all the components, especially
the connectors of air guide louver.
Step Picture Work instruction
Remove the air guide
louver assembly.
Remove the air guide louver
from its supporting
assembly. Then take off the
connectors from the swing
motor. (As shown in the
picture, the lines indicate the
supporting assembly.)
Removal of water tray
Note: Before removal, make sure power is cut off. During the removal procedure, take good care of all the components.
Step Picture Work instruction
Remove the water tray. Remove the water tray.
Removal of evaporator
Note: Make sure power is cut off. Take good care of the copper pipe and aluminum fins. If the removal takes a long time, seal
the
copper pipe.
Step Picture Work instruction
Remove the evaporator
assembly.
Twist off the 6 screws of the
evaporator, 3 screws of the
plate board of water
releasing flume, and 2
screws of the water tray.
Then remove the evaporator.
Removal of display panel and fan assembly
Note: Before removal, make sure power is cut off. During the removal procedure, take good care of all the components.
Step Picture Work instruction
Remove the display panel
and fan assembly.
First remove the display
panel, next the bracket and
then the swing motor
mounting plate.

Table of Contents