GREE         U-Match 5 SERIES UNIT SERVICE MANUAL 
14 
second time in a certain time period, system will not restore operation. You need to manually turn off the unit and 
clear the error before restarting up the unit. (If high pressure protection occurs frequently, please send for 
professional personnel to repair.) 
2.2.3.2 Low Pressure Protection Control 
System will enable low pressure protection control if the low pressure switch is detected open for 
continuously a little time. Under low pressure protection, system will be shut down and display error code E3. 
When low pressure protection occurs, system will restore operation if the low pressure switch is detected to be 
reclosed within a few minutes after shutdown. If low pressure protection occurs for several times in a period of 
time, system will not restore operation automatically. You need to manually turn off the unit before restarting up 
the unit. 
2.2.3.3 High Temperature Prevention Control 
Under heating mode, system will enable high temperature prevention control if the temperature sensed by 
indoor tube temperature sensor reaches a certain value. When high temperature prevention control is enabled, 
outdoor fan will slow down. 
2.3 Functions 
2.3.1 Setting of Filter Cleaning Reminder 
When setting washing remind function, the timer area will display 2–bit number that means the pollution level, 
then press “▲” and “▼” buttons to select, and press “SWING/ENTER” button to confirm the setting. Conversion 
relation between the displayed pollution level and accumulative operating time are as the following list. After 
setting, when it reaches the washing time, “CLEAN” icon will flash and remind, if you press “▲” and “▼” buttons 
to adjust the level, and press “SWING/ENTER” button, then the accumulative time for filter washing remind will 
not be reset; If the time after adjustment is larger than the current accumulative time, then “CLEAN” icon will stop 
flashing; If the time after adjustment is less than the current accumulative time, then “CLEAN” icon will continue to 
flash.   
The only method for cancelling the remind function is to press “FUNCTION” button to switch to “CLEAN” icon, 
and set the timer area to be “00”, and then press “SWING/ENTER” button, then the accumulative time of filter 
washing remind is reset. 
Pollution Level 
Accumulated 
Operating Time 
(hour) 
Pollution Level 
Accumulated 
Operating Time 
(hour) 
Pollution Level 
Accumulated 
Operating Time 
(hour) 
10  5500  20  1400  30  100